Appliance Error Codes

Find solutions for common appliance error codes.

Samsung Error Codes

CodeProblem Description
E464IPM Over Current overload
E461Compressor not starting
E473Compressor blocking
E466DC Link card voltage error
E221Outdoor temp. sensor error
E416Discharge Temp. Overheat
E251Discharge temp. sensor error
E468Electric current sensor error
E465Compressor error
E237Winding error of the temp. sensor
E202Connection time (1 minute) expired
E458Fan Error (Outdoor)
E471OTP error
E467Compressor rotation/Wire Missing
E440Operation condition secession Low
E441Operation condition secession High
E469DC error of the voltage sensor
E462Trip error / PFC Over current
E554Leak of refrigerant
E472Zero crossing of the AC voltage
E556Capacity Miss-match
E121Internal air temp. sensor is closed / cut off
E122Evaporator temp. sensor closed / cut off
E154Indoor unit fan error
E101Connection time (1 minute) exceeded / Indoor to Outdoor Wiring issue
E102Indoor to Outdoor Wiring issue
E121ROOM Temp. sensor error
E122INDOOR MID, INDOOR IN PIPE-Temp. sensor
E154Fan Error (Indoor)
E162EEPROM (Indoor motor)
E231Cond Temp. Sensor
E422EEV or Valve Close error-Self diagnosis
E470EEPROM Data Error (no data)
E471EEPROM Data Error (Main Micom Inv Micom)
E474Heatsink Sensor Error
E483Over Voltage Protection
E484PFC Over Load
E485Input Current Sensor
E488AC Input Voltage Sensor
E500Heatsink Over Temperature Error
E554Gas Leak Error
E163Option Error
E203Time out Comm. (Inv Micom Main Micom)
E440Over(Heating) Error
E441Prohibit Operation Condition Error (Cooling)

LG Error Codes

CodeProblem Description
C1 or CH1Indoor temperature sensor open or closed circuit.
C2 or CH2Outdoor temperature sensor open or closed circuit.
C4 or CH4Heat sink temperature sensor open or closed circuit.
C5 or CH5Communication between indoor and outdoor units.
C6 or CH6Excessive current at inverter DC power circuit.
C7 or CH7Excessive compressor current.
C8 or CH8Indoor fan not rotating.
C9 or CH9Outdoor fan not rotating.
CA or CH10Faulty discharge thermistor.
CADischarge temp more than 130 °C or Faulty discharge thermistor.
CCEEPROM error.
CDInverter module error.
PoSystem in Power Mode – not a fault.
LoSystem in test mode – not a fault.
Error 41Inverter Compressor discharge Thermistor fault.
Error 44Outdoor unit air Thermistor fault.
Error 45Condenser coil outlet Thermistor fault.
Error 46Compressor suction Thermistor fault.
Error 47Inverter Compressor discharge Thermistor fault.
Error 39PCB defect / Wiring defect / ODU Inverter PCB assembly damage.
Error 01Indoor unit return air Thermistor fault.
Error 02Indoor unit coil inlet Thermistor fault.
Error 03Wiring error between the remote controller and the fan coil.
Error 04Float switch fan fault.
Error 05Communication indoor and outdoor fault.
Error 06Indoor unit coil outlet Thermistor fault.
Error 09EEPROM connects on Main PCB fault.
Error 10Indoor Fan Motor problem.
Error 21Over current in the inverters DC power circuit.
Error 22Compressor over-current.
Error 25Problem with incoming power supply to the system.
Error 26Inverter compressor indicates a seized compressor.
Error 27Inverter module fault.
Error 28DC Voltage in inverter is too high.
Error 29Overload operation/Compressor damage/Motor damage/Input Voltage Low/ODU Inverter PCB assembly damage.
Error 32Inverter compressor discharge temperature is high (above 105ºC).
Error 73Overload operation/Compressor damage/Motor damage/Input Voltage Low/ODU Inverter PCB assembly damage.
Error 67Outdoor Fan Motor fault.
Error 65Inverter PCB heat sink thermistor fault.
Error 62Outdoor unit Inverter heat-sink thermistor fault.
Error 61Indicates the outdoor unit condenser coil temperature is high above 65ºC.

Panasonic Error Codes

CodeProblem Description
S01Room temperature sensor failure
S02Indoor coil sensor failure
S03Humidity sensor failure
S04Comp. temperature sensor failure
S05Outdoor coil sensor failure
S06Outdoor air sensor failure
S07Outdoor current sensor failure
E01Indoor/outdoor communication failure
E02HIC circuit failure (Compressor/Fan circuit)
E03Outdoor unit OTP rom failure
E04Peak current cut off
E05PAM or Active circuit failure
E06High compressor discharge temperature
E07Indoor fan operating failure
E08Way valve switching failure (RV)
E09No refrigerant protection
E10DC compressor drive circuit failure
E11Outdoor fan operating failure
E12Error in outdoor unit
H00No abnormality detected
H11Indoor-outdoor abnormal communication
H14Indoor intake air temperature sensor abnormality
H15Outdoor compressor temperature sensor abnormality
H16Outdoor Current Transformer open circuit
H19Indoor fan motor abnormality
H23Indoor heat exchanger temperature sensor abnormality
H24Indoor heat exchanger temperature sensor 2 abnormality
H27Outdoor air temperature sensor abnormality
H28Outdoor heat exchanger temperature sensor abnormality
H30Outdoor discharge air temperature sensor abnormality
H33Indoor/Outdoor wrong connection
H38Indoor/outdoor mismatch (brand code)
H97Outdoor fan motor mechanism locked
H98Indoor high pressure abnormality
H99Indoor heat exchanger anti-freezing abnormality
F11Cooling/Heating cycle changeover abnormality
F90PFC control abnormality
F91Refrigeration cycle abnormal
F93Outdoor compressor abnormal revolution
F95Cool high pressure abnormality
F96IPM (power transistor) overheating
F97Outdoor compressor overheating
F98Total running current abnormality

Haier Error Codes

CodeProblem Description
E1Indoor room temperature sensor failure
E2Indoor coil temperature sensor failure
E4EEPROM wrong
E7Communication failure between indoor and outdoor
E14Indoor fan motor failure
E18Temperature cutoff
F1Module failure
F2Outdoor DC motor failure
F4Compressor overheat / discharging temperature
F5Module over current / current transducer failure
F6Outdoor ambient temp. sensor
F7Outdoor suction/defrosting temp. sensor
F8High pressure
F9Low pressure
F10No AC power supply
F11Outdoor PCB EEPROM
F13Communication failure outdoor PCB and module
F14Compressor discharging temp. sensor failure
F15Compressor running faulty
F16Running state-detecting circuit failure

Hitachi Error Codes

CodeProblem Description
P01Pressure ratio
P02High pressure increase
P03Inverter current high
P04Inverter fin temperature increase
P05Discharge gas temp. increase
P06Low pressure decrease
P09High pressure decrease
P0ADemand current control
P0dLow pressure increase
P11Pressure ratio decrease
P12Low pressure increase
P13High pressure increase
P14compressor overcurrent
P15Discharge gas temp. increase/ Low pressure
P16Discharge gas super-heat
P26High pressure decrease
01Failure of Fan Motor, Drain Discharge, PCB, Relay
03Incorrect Wiring. Failure of PCB. Tripping of Fuse
05Incorrect Wiring
06Voltage and Power Supply issue, Incorrect Wiring
07Over Refrigerant Charge, Expansion Valve Open Lock
08Ref. Leakage
09Failure of Fan Motor
11Inlet Air Thermistor Failure
12Outlet Air Thermistor Failure
14Gas Piping Thermistor Failure
19Failure of Fan Motor
21High Pressure Sensor Failure
22Outdoor Air Thermistor Failure
23Discharge Gas Thermistor on Comp Failure
24Evaporating Thermistor Failure
29Low Pressure Sensor Failure

Carrier Error Codes

CodeProblem Description
E1Indoor / outdoor communication error
E3Indoor fan Motor error
E4Indoor room temp. sensor error
E5Evaporator coil temp. sensor error
ECRefrigerant Leakage detection
F1Outdoor temp sensor open or short circuit
F2Condenser coil temp. sensor open or short circuit
F3Compressor discharge temp. sensor error
F4Outdoor unit EEPROM parameter error
F5Outdoor fan speed has been out of control
P0IPM malfunction or IGBT over-strong current protection
P1Over voltage or over low voltage protection
E0Outdoor EEPROM malfunction
E2Indoor/outdoor units communication protection
E3Communication error between IPM board and outdoor main board
E4Open or short circuit of outdoor temp. sensor
E8Outdoor fan speed has been out of control
F1Indoor unit coil pipe connector of sensor is defective
F2Indoor unit coil pipe connector of sensor is defective
F3Indoor unit coil pipe connector of sensor is defective
08Defrost Mode 1
0ADefrost Mode 2
F0Low charge or refrigeration system blockage
F3Outdoor ambient temperature sensor malfunction
F4Outdoor mid-coil temperature sensor malfunction
F5Outdoor discharge air temperature sensor malfunction
F7Cooling oil return cycle
E1System high pressure protection
E2Indoor freeze protection
E3System low pressure protection
E4Compressor discharge high temperature protection
E6Communication error between indoor and outdoor units
E7Mode conflict
E8System overload protection
E9Cold Blow
ddTest mode
FoPump down mode
P0IPM Rest
P5Compressor current protection
P6Communication error between the inverter drive and main board
P7Heat sink temperature sensor malfunction
P8IPM over temperature protection
P9Open Contactor
PcCurrent sensor malfunction
PdCurrent sensor mis-wiring protection
PAInput current protection
PFInverter board ambient temperature sensor malfunction
PLLow voltage protection
PHHigh voltage protection
PPAbnormal input AC voltage
PUCapacitor charging malfunction
H1Heating oil return cycle
H2Forced defrost
H3Compressor overheat protection
H5IPM Protection
H7Compressor speed reduction due to abnormal module temperature
HcPFC board protection
L9Compressor high voltage protection
LcCompressor start-up failure
LdCompressor phase loss
LECompressor stalling
LFCompressor over-speed
A5Condenser coil inlet temp sensor malfunction
A7Condenser outlet temperature sensor malfunction
EEMemory card error
EnFrequency limitation for module circuit protection
EUFrequency limitation for module temperature protection
F6Frequency limitation for overload protection
F8Frequency limitation for system circuit protection
F9Frequency limitation for module circuit protection
FHFrequency limitation for freeze protection
HECompressor demagnetizing protection
LPIndoor and outdoor units mismatch
U1Compressor phase detection malfunction
U3Low DC bus voltage
dnCommunication error between main board and EXV board
13Unit A indoor pipe outlet temperature sensor malfunction
14Unit A indoor pipe inlet temperature sensor malfunction
15Unit A Indoor return air sensor malfunction
16Unit A mode conflict
17Unit A freeze protection
23Unit B indoor pipe outlet temperature sensor malfunction
24Unit B indoor pipe inlet temperature sensor malfunction
25Unit B Indoor return air sensor malfunction
26Unit B mode conflict
27Unit B freeze protection
33Unit C indoor unit pipe outlet temperature sensor malfunction
34Unit C indoor unit pipe inlet temperature sensor malfunction
35Unit C Indoor unit return air sensor malfunction
36Unit C mode conflict
37Unit C freeze protection
41Unit D communication error
42Indoor return air temperature sensor malfunction
43Unit D indoor pipe outlet temperature sensor malfunction
44Unit D indoor pipe inlet temperature sensor malfunction
45Unit D Indoor return air temperature sensor malfunction
46Unit D mode conflict
47Unit D freeze protection
51Unit E communication error
52Unit E indoor pipe midway temperature sensor malfunction
53Unit E indoor pipe outlet temperature sensor malfunction
54Unit E indoor pipe inlet temperature sensor malfunction
55Unit E Indoor return air temperature sensor malfunction
56Unit E mode conflict
57Unit E freeze protection
C5Jumper missing on replacement indoor board

IFB Error Codes

CodeProblem Description
E1Indoor temperature sensor. RUN lamp: flashes once.
E2Indoor pipe temperature sensor. RUN lamp: flashes twice.
E6Malfunction of indoor fan motor. RUN lamp: flashes 6 times.

Mitsubishi Error Codes

CodeProblem Description
A6Communication error with communication processor
EAMis-wiring/loose inter-connecting cables. Noise interference
EBMis-wiring/loose interconnecting cables.
ECStart-up time over. The unit has failed to initialise after power up.
EDSerial communication error.
EFNon-defined error code. Noise interference - power down outdoor unit for 30 seconds then switch back on
E0Remote controller communication error - check wiring, connections and comms voltage.
E1Remote controller issue - check wired to master indoor only
E2Remote controller issue check wired to master indoor only
E3Remote controller issue - not transmitting check wired to master indoor only
E4Remote controller issue - not receiving, check wired to master indoor only
E5Remote controller issue, check wired to master indoor only
E6Indoor/outdoor communication error
E7Comms fault between I/C and O/C - check for condensate pump at I/C, reset power to O/C, check 12/24Vdc on S2 and S3 possible I/C board failure
E8Comms failure indoor to outdoor (S2/S3) - check pumps wired in, check indoor isolator and re-power in correct sequence i.e. indoor then outdoor
E9Comms failure indoor to outdoor (S2/S3) - check pumps wired in, check indoor isolator and re-power in correct sequence i.e. indoor then outdoor
FA51CM connector open -
F1Reverse phase detection -
F2L3 phase open - check power supply, also check for open circuit protection devices
F363L open - check low pressure switch for disconnection or contact failure.
F449C open - compressor inner thermostat for open circuit or contact failure
F563H open - check high pressure switch for disconnection or contact failure.
F7- faulty outdoor board
F8outdoor board defective
P1Return air thermistor fault (TH1) -
P2Liquid pipe thermistor fault (TH2) check if TH2 disconnected or open or close circuit
P4Drain sensor fault
P5High condensate level - drain pump failure
P6reduced air flow through indoor coil. Dirty filters. Fan motor problem. Blockage
P8mainly caused by refrigerant leakage
P9TH5 condenser/evaporator thermistor open
U1outdoor fan failure, blocked coil, blockage in the system, blocked filters on indoor in heating
U2compressor over heating due to lack of refrigerant,
U3Discharge thermistor fault
U4Outdoor thermistor fault
U5Inverter heat sink temperature too high (TH8)
U6Compressor over current
U7Low discharge superheat

Onida Error Codes

CodeProblem Description
E1High pressurecompressor
E2Indoor anti-frozen
E3Low pressure protection of compressor
E4Discharge temp
E5Compressor overload
E6Transmit malfunction
F0Indoor sensor mal-function
F1Indoor pan tube inlet tube temp.
F2Indoor pan tube middle temp. sensor malfunction
F3Indoor pane tube outlet tube temp. sensor malfunction
F4Outdoor environment temp. sensor malfunction
F5Outdoor pan tube inlet tube temp. sensor malfunction
F6Outdoor pan tube middle temp. sensor malfunction
F7Outdoor pan tube outlet tube temp. sensor malfunction
F8Discharge temp. sensor 1 (rated frequency) malfunction
F9Discharge temp. sensor 2 (digital) malfunction
FAGreasy temp. temp. sensor 1 (rated frequency) malfunction
FbGreasy temp. temp. sensor 2 (digital) malfunction
FCHigh pressure sensor malfunction
FdLow pressure sensor malfunction

LIOYAD Error Codes

CodeProblem Description
E2Room temperature sensor checking channel is abnormal. LED 2 Timer: Flashing
E3Pipe temperature sensor checking channel is abnormal. LED 1 Operation: Flashing
E4Outdoor pipe TEMP. sensor checking is abnormal. LED 3 Def.Fan: Flashing
E6Outdoor malfunction. LED 1, LED 2, LED 3, LED 4 : Flashing
E7EEPROM malfunction. LED 1, LED 2 : Flashing
E8Water-level alarm malfunction. LED 4 Alarm: Flashing

Electrolux Error Codes

CodeProblem Description
EEEEPROM Malfunction
E3Refrigeration System Blocked/Gas Leak
E4Compressor High Temp
E5AC-Over Current
E6Communications Fault
E8Anti-High Temperature
F1Sensor, Room Temperature (Indoor)
F2Sensor, Tube Temperature (Indoor)
F3Sensor, Ambient (Outdoor)
F4Sensor, Coil (Outdoor)
F5Sensor, Compressor Discharge (Outdoor)
F6Anti-High Temperature
H3Compressor Overload Protection
H5IPM Protection
H6Fan Stall, Indoor Unit
HCPFC Protection
P1Compressor Rated Frequency
P2Compressor Maximum Frequency
P3Compressor Medium Frequency
PHHigh Voltage
PLLow Voltage Protection
POCompressor Minimum Frequency
LPIndoor & Outdoor Units Don’t Match
L3Outdoor DC Fan Motor Malfunction
C5Jumper Cap Malfunction
d1Compressor off

Bosch Error Codes

CodeProblem Description
E0Indoor unit EEPROM parameter error
E1Indoor / outdoor units communication error
E2Zero-crossing signal detection error
E3Indoor fan speed has been out of control
E4Indoor room temperature sensor T1 open circuit or short circuit
E5Evaporator coil temperature sensor T2 open circuit or short circuit
ECRefrigerant leakage detection
F0Overload current protection
F1Outdoor ambient temperature sensor T4 open circuit or short circuit
F2Condenser coil temperature sensor T3 open circuit or short circuit
F3Compressor discharge temperature sensor T5 open circuit or short circuit
F4Outdoor unit EEPROM
F5Outdoor fan speed has been out of control
P0IPM malfunction or IGBT over
P1Over voltage or over low voltage protection
P2High temperature protection of IPM module or compressor top
P3*Outdoor ambient temperature too low.
P4Inverter compressor drive error
P5Indoor units mode confl ict (multi-zone ONLY)

Daikin Error Codes

CodeProblem Description
A1Indoor PCB defect
A6Indoor Fan motor overload
A7swing motor flap
C3Indoordrain thermistor
C4Indoor coil sensor
C5Suction pipe sensor
C7Front panel driving motor fault
CAIndoor discharge air thermistor
E1Outdoor PCB defect
E3Outdoor high pressure switch
E4Outdoor Low pressure switch
E5Inverter compressor overheat
E6Outdoor Compressor start up error
E7Outdoor Fan motor Defective
E8Outdoor Invertercompresso overcurrent
EAOutdoor Four way valve defective
F6Outdoor Refrigerant overcharged
FCOutdoor Low pressure drop
AHFailure of dust collector
C6Failure of fan motor
F3High discharge temperature
F6High pressure in cooling
H9Failed ambient sensor
J3Failed discharge pipe sensor
J5Failed suction pipe sensor
J6Failed outdoor coil sensor
J9Failed sub cool heat exchanger sensor
UAIndoor / outdoorcommunication
UORefrigerant short
U0Refrigerant shortage
U2Low-voltage detection or over-voltage detection
U4Signal transmission error (between indoor unit and outdoor unit)
UAUnspecified voltage (between indoor unit and outdoor unit)
A1Indoor unit PCB (IN DOOR )
A5Freeze-up protection control or heating peak-cut control (IN DOOR )
A6Fan motor or (IN DOOR )
C4Indoor heat exchanger (IN DOOR )
C9Room temperature thermistor (IN DOOR )
E1Outdoor unit PCB (OUT DOOR )
E5(compressor overload) (OUT DOOR )
E6Compressor lock (OUT DOOR )
E7DC fan lock (OUT DOOR )
E8Input overcurrent detection (OUT DOOR )
EAFourWay valve (OUT DOOR )
F3Discharge pipe temperature control (OUT DOOR )
F6High pressure control in cooling (OUT DOOR )
H0Compressor system sensor (OUT DOOR )
H6Position sensor (OUT DOOR )
H8DC voltage / current sensor (OUT DOOR )
H9Outdoor temperature thermistor (OUT DOOR )
J3Discharge pipe thermistor (OUT DOOR )
J6Outdoor heat exchanger thermistor (OUT DOOR )
L3Electrical box temperature rise (OUT DOOR )
L4Radiation fin temperature rise (OUT DOOR )
L5Output overcurrent detection (OUT DOOR )
U7Signal transmission error on outdoor unit PCB (OUT DOOR )

Godrej Error Codes

CodeProblem Description
E1System Hi Pressure Protection
E2Inner anti-frozen protection
E3System Low Pressure Protection
E4Compressor Discharge Pressure
E5Low Voltage Over-current Protect
E6Communication Failure
E7Mode Conflict
E8Anti-Hi Temp Protection
E9Anti Cold Wind Protection
E0Lower running frequency due Low-Voltage of Power Supply
H6No response from indoor motor. PCB failure
F1Indoor environment temp. sensor short or open circuit
F2Indoor evaporator temp. sensor short or open circuit
F3Outdoor environment temp. sensor short or open circuit
F4Outdoor condenser temp. sensor short or open circuit
F5Outdoor discharge temp. sensor short or open circuit
F6Lower running frequency due to cooling overloaded
F7Oil return in cooling mode
F8lower running frequency due to over current
F9lower running frequency due discharge pressure too high
H1Defrost
H2Static dust removing protection
H3Compressor overload protection
H4System abnormal
H5Module protection
H7Synchronization failure
H8Water full protection
H9Electric Heater Malfunction
H0Lower frequency for antihigh-temp in heating mode
FALower running frequency due to high pipe temp.
FHLower running frequency due to anti-freeze
C5No Jumper

Whirlpool Error Codes

CodeProblem Description
UASetting error, indoor and outdoor
E6Communication malfunction
PLDC input voltage is too low
PHDC input voltage is too high
P7Temperature sensor malfunction of carbon fin
UUDC overcurrent
P8Overheat of carbon fin
F4Break-circuit and short-circuit of outdoor condenser temperature sensor
F5Break-circuit and short-circuit of outdoor discharge temperature sensor
E4Discharge protection of compressor
F3Outdoor ambient temperature sensor malfunction
U5Current diction malfunction of complete unit
EEIndoor PCB malfunction
H4Overload of system
H6No motor of indoor unit feedback
F2Indoor pipe temperature sensor malfunction
F1Internal ambient temperature sensor malfunction
UFZero passage abnormal
H3Overload of compressor
LcStartup failure
UHNo motor of outdoor unit feedback
E5Overcurrent protection
U74-way valve conversion abnormal
U1Phase current detection malfunction of compressor

SHARP Error Codes

CodeProblem Description
EEButtons are locked
E0Water pump malffunction
E1High pressure protection of compressor
E2Indoor anti-frozen of compressor
E3Low pressure protection of compressor
E4Air discharge high-temperature protection of compressor
E5Overload protection of compressor
E8Indoor fan protection
E9Water flow protection
FFConnected control communications Failure
F0Malfunction of indoor environment sensor at air return vent
F1Evaporator sensor malfunction
F2Condenser sensor malfunction
F3Outdoor environment sensor malfunction
F4Malfunction of air discharge sensor
F5Malfunction of environment sensor on displayer

Voltas Error Codes

CodeProblem Description
E1Room Temp Sensor error
E2Coil Temp Sensor error
E3Outdoor coil temp sensor error
EFDefrosting message for IDU coil
dFDefrosting message for ODU coil
E1Room Temp Sensor error
E2Coil Temp Sensor error
dFDefrosting message for IDU coil